XCKM102
XCKM102 - Telemecanique Sensors
Limit switch, Limit switches XC Standard, XCKM, steel roller plunger, 1NC+1 NO, snap action, Pg11
IN STOCK
Description
This XCKM classic format limit switch has a steel roller plunger and a Zamak body. This limit switch has a robust Zamak body, 3 cable entries, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.
Main | |
Range of product | Telemecanique Limit switches XC Standard |
---|---|
Series name | Standard format |
Product or component type | Limit switch |
device short name | XCKM |
body type | Fixed |
Head type | Plunger head |
Material | Metal |
body material | Zamak |
fixing mode | By the body |
Movement of operating head | Linear |
Type of operator | Spring return roller plunger metal |
Type of approach | Lateral approach, 2 directions |
Cable entry | 3 entries tapped for Pg 11 cable gland |
Number of poles | 2 |
contacts type and composition | 1 NC + 1 NO |
contact operation | Snap action |
Complementary | |
Switch actuation | By 30° cam |
---|---|
Electrical connection | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Contacts insulation form | Zb |
Number of steps | 1 |
Positive opening | With |
Positive opening minimum force | 36 N |
Minimum force for tripping | 12 N |
Minimum actuation speed | 0.01 m/min |
Maximum actuation speed | 0.5 m/s |
Contact code designation | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current | 10 A AC |
[Ui] rated insulation voltage | 300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 |
Maximum resistance across terminals | 25 MOhm conforming to IEC 60255-7 category 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
Short-circuit protection | 10 A cartridge fuse, type gG |
Electrical durability | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability | 20000000 cycles |
Width | 64 mm |
Height | 64 mm |
Depth | 30 mm |
Net weight | 0.255 kg |
Terminals description ISO n°1 | (21-22)NC (13-14)NO |
Specifications
Main Range of product Telemecanique Limit switches XC Standard Series name Standard format Product or component type Limit switch device short name XCKM body type Fixed Head type Plunger head Material Metal body material Zamak fixing mode By the body Movement of operating head Linear Type of operator Spring return roller plunger metal Type of approach Lateral approach, 2 directions Cable entry 3 entries tapped for Pg 11 cable gland Number of poles 2 contacts type and composition 1 NC + 1 NO contact operation Snap action Complementary Switch actuation By 30° cam Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² Contacts insulation form Zb Number of steps 1 Positive opening With Positive opening minimum force 36 N Minimum force for tripping 12 N Minimum actuation speed 0.01 m/min Maximum actuation speed 0.5 m/s Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A[Ithe] conventional enclosed thermal current 10 A AC [Ui] rated insulation voltage 300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1Short-circuit protection 10 A cartridge fuse, type gG Electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix CMechanical durability 20000000 cycles Width 64 mm Height 64 mm Depth 30 mm Net weight 0.255 kg Terminals description ISO n°1 (21-22)NC
(13-14)NO