top of page
XCKM102

XCKM102

SKU: TR
$29.82Price

XCKM102 - Telemecanique Sensors

Limit switch, Limit switches XC Standard, XCKM, steel roller plunger, 1NC+1 NO, snap action, Pg11

IN STOCK

Description

This XCKM classic format limit switch has a steel roller plunger and a Zamak body. This limit switch has a robust Zamak body, 3 cable entries, a modular design allowing easier maintenance and a classic format. It is IP66 and IK05 impact resistant, making it ideal for heavy duty use in harsh conditions. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508, BV standards. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

Main
Range of productTelemecanique Limit switches XC Standard
Series nameStandard format
Product or component typeLimit switch
device short nameXCKM
body typeFixed
Head typePlunger head
MaterialMetal
body materialZamak
fixing modeBy the body
Movement of operating headLinear
Type of operatorSpring return roller plunger metal
Type of approachLateral approach, 2 directions
Cable entry3 entries tapped for Pg 11 cable gland
Number of poles2
contacts type and composition1 NC + 1 NO
contact operationSnap action
Complementary
Switch actuationBy 30° cam
Electrical connectionScrew-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation formZb
Number of steps1
Positive openingWith
Positive opening minimum force36 N
Minimum force for tripping12 N
Minimum actuation speed0.01 m/min
Maximum actuation speed0.5 m/s
Contact code designationA300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A AC
[Ui] rated insulation voltage300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability20000000 cycles
Width64 mm
Height64 mm
Depth30 mm
Net weight0.255 kg
Terminals description ISO n°1(21-22)NC
(13-14)NO
  • Specifications

    Main
    Range of product Telemecanique Limit switches XC Standard
    Series name Standard format
    Product or component type Limit switch
    device short name XCKM
    body type Fixed
    Head type Plunger head
    Material Metal
    body material Zamak
    fixing mode By the body
    Movement of operating head Linear
    Type of operator Spring return roller plunger metal
    Type of approach Lateral approach, 2 directions
    Cable entry 3 entries tapped for Pg 11 cable gland
    Number of poles 2
    contacts type and composition 1 NC + 1 NO
    contact operation Snap action
    Complementary
    Switch actuation By 30° cam
    Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
    Contacts insulation form Zb
    Number of steps 1
    Positive opening With
    Positive opening minimum force 36 N
    Minimum force for tripping 12 N
    Minimum actuation speed 0.01 m/min
    Maximum actuation speed 0.5 m/s
    Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
    Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current 10 A AC
    [Ui] rated insulation voltage 300 V conforming to UL 508
    500 V (pollution degree 3) conforming to IEC 60947-1
    300 V conforming to CSA C22.2 No 14
    Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
    [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
    6 kV conforming to IEC 60947-1
    Short-circuit protection 10 A cartridge fuse, type gG
    Electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
    Mechanical durability 20000000 cycles
    Width 64 mm
    Height 64 mm
    Depth 30 mm
    Net weight 0.255 kg
    Terminals description ISO n°1 (21-22)NC
    (13-14)NO
No Reviews YetShare your thoughts. Be the first to leave a review.