GZ1E06 - SCHNEIDER
Easy TeSys Motor protection switch GZ1E - 3 poles - 1..1,6A - thermal magnetic protection
In Stock
Explanation
GZ1 E are 3-pole 3d thermal magnetic circuit breakers specially designed for the control and protection of motors in accordance with IEC 60947-2 and IEC 60947-4-1 standards. Setting range of thermal trips, with thermomagnetic trip unit 1-1 GV2 IP 41 and GV2 in MC01 box Provides IP 55 protection in the MC02 enclosure. 0.1 MLoops provide standard reliability and durability with electrical/mechanical durability These circuit breakers are designed for connection with screw clamp terminals Available worldwide, multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHS/REACh) These circuit breakers are designed for connection with screw clamp terminals Available worldwide, multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHS/REACh)
Complementary
pole definition 3P Network type HUNGRY usage category AC-3 network frequency 50/60 Hz conforming to IEC 60947-2 Mounting Type
Clip With Screwsmounting support Rail mounting position Any location engine power kW 0.37 kW at 400 V AC 50/60 Hz
0.55 kW at 440 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 690 V AC 50/ 60HzBar description Icu: >= 100 kA at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Icu: >= 100 kA at 690 V AC 50 /60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type On/off button thermal protection adjustment range 1…1.6 A magnetic tripping current 22.5A [Ue] nominal operating voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] nominal insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] nominal impulse withstand voltage 6 kV conforming to IEC 60947-2 power distribution 2.5W (per pole) Mechanical durability 100000 cycles electrical durability AC-3 for 100000 cycles maximum working rate 25 cyc/h connections - terminals Screw clamp terminals 2 1…6 mm² - cable stiffness: solid
Screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable end
Screw clamp terminals 2 1…4 mm² - cable stiffness: flexible With cable endHeight 89mm Width 44.5mm Depth 78mm Product weight 0.26kg Environmental
standards IEC 60947-4
IEC 60947-2preventive maintenance T.H. IP protection degree IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C Storage environmental conditions -40…80 °C fire resistance 960 °C conforming to IEC 60695-2-1 working height 2000m