ATV610D55N4
ATV610D55N4 - SCHNEIDER
variable speed drive ATV610 - 55 kW/75 HP - 380...415 V - IP20
stock : 5
Description
This Easy Altivar 610 drive is a frequency inverter for three-phase asynchronous motors. It works at a rated supply voltage from 380V to 415V AC. It is suitable for motors with power rating up to 55kW / 75hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 45kW / 60hp for applications requiring significant overload (up to 150%). It offers a plug & play solution, whereby parameters are preset in the factory to the desired configuration, to help save process control and operating time. It has integrated radio interference input filters in accordance with the EMC standard for variable speed electrical power drive “products” IEC/EN 61800-3, edition 2, category C3 in environment 1 or 2. It weighs 53.7kg and its dimensions are, 290mm wide, 762mm high, 323mm deep. this drive has been specially designed for standard applications in the market segments water and wastewater and oil and gas and in the domains process and machine management and building management.
Read Less.
Specifications Main
Main Range of product Easy Altivar 610 Product or component type Variable speed drive Product specific application Fan, pump, compressor, conveyor Device short name ATV610 variant Standard version product destination Asynchronous motors
Synchronous motorsmounting mode Cabinet mount EMC filter Integrated conforming to IEC 61800-3 category C3 with 50 m IP degree of protection IP20 Type of cooling Forced convection Supply frequency 50...60 Hz +/-5 % Network number of phases 3 phases [Us] rated supply voltage 380...460 V - 15...10 % Motor power kW 55 kW for normal duty
45 kW for heavy dutyMotor power hp 75 hp for normal duty
60 hp for heavy dutyLine current 111.5 A at 380 V (normal duty)
99.7 A at 460 V (normal duty)
95.9 A at 380 V (heavy duty)
84.0 A at 460 V (heavy duty)Prospective line Isc 22 kA Apparent power 79.5 kVA at 460 V (normal duty)
66.9 kVA at 460 V (heavy duty)Continuous output current 88 A at 2.5 kHz for heavy duty
120 A at 2.5 kHz for normal dutyMaximum transient current 132 A during 60 s (heavy duty)
132 A during 60 s (normal duty)Asynchronous motor control profile Optimized torque mode
Constant torque standard
Variable torque standardOutput frequency 0.1…500 Hz Nominal switching frequency 2.5 kHz Switching frequency 1...8 kHz adjustable number of preset speeds 16 preset speeds Communication port protocol Modbus serial Option card Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output cardComplementary
Output voltage <= power supply voltage Motor slip compensation Automatic whatever the load
Adjustable
Not available in permanent magnet motor law
Can be suppressedAcceleration and deceleration ramps S, U or customized
Linear adjustable separately from 0.01 to 9000 sBraking to standstill By DC injection Protection type Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: driveFrequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 HzElectrical connection Control, screw terminal: 0.5...1.5 mm²
Line side, screw terminal: 70...120 mm²
Motor, screw terminal: 70...120 mm²Connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial Physical interface 2-wire RS 485 for Modbus serial Transmission frame RTU for Modbus serial Transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial Type of polarization No impedance for Modbus serial Number of addresses 1…247 for Modbus serial Method of access Slave Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionLocal signalling 2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltageWidth 290 mm Height 762 mm
922 mm with EMC plateDepth 323 mm Net weight 53 kg Analogue input number 3 Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensorDiscrete input number 6 Discrete input type DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)Input compatibility DI1...DI6: logic input level 1 PLC conforming to IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68Discrete input logic Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)Analogue output number 2 Analogue output type Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
10 ms +/- 1 ms (AQ1, AQ2) - analog outputAccuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog outputLinearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog outputRelay output number 3 Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cyclesRefresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DCIsolation Between power and control terminals Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth Environment
Noise level 78 dB conforming to 86/188/EEC Power dissipation in W 969 W(forced convection) at 380 V, switching frequency 2.5 kHz
131 W(natural convection) at 380 V, switching frequency 2.5 kHzVolume of cooling air 295 m3/h Operating position Vertical +/- 10 degree Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6Pollution degree 2 conforming to IEC 61800-5-1 Vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3 Ambient air temperature for operation -15…45 °C (without derating)
45…60 °C (with derating factor)ambient air temperature for storage -40…70 °C Operating altitude <= 1000 m without derating
1000...4800 m with current derating 1 % per 100 mEnvironmental characteristic Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to IEC 60721-3-3Standards IEC 61800-3
Environment 2 category C3 IEC 61800-3
IEC 61800-5-1
IEC 60721-3Marking CE Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 47.000 cm Package 1 Width 59.000 cm Package 1 Length 87.000 cm Package 1 Weight 70.500 kg Properties
variable speed drive ATV610 - 55 kW/75 HP - 380...415 V - IP20
- Compact size
- Easy and quick installation
- User-friendly graphic display terminal
- Easy integration on an enclosure door
- Colored control circuit terminals to avoid misuse
-
1 week delivery time