ATV610D55N4 - SCHNEIDER

variable speed drive ATV610 - 55 kW/75 HP - 380...415 V - IP20

stock : 5

Description

This Easy Altivar 610 drive is a frequency inverter for three-phase asynchronous motors. It works at a rated supply voltage from 380V to 415V AC. It is suitable for motors with power rating up to 55kW / 75hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 45kW / 60hp for applications requiring significant overload (up to 150%). It offers a plug & play solution, whereby parameters are preset in the factory to the desired configuration, to help save process control and operating time. It has integrated radio interference input filters in accordance with the EMC standard for variable speed electrical power drive “products” IEC/EN 61800-3, edition 2, category C3 in environment 1 or 2. It weighs 53.7kg and its dimensions are, 290mm wide, 762mm high, 323mm deep. this drive has been specially designed for standard applications in the market segments water and wastewater and oil and gas and in the domains process and machine management and building management.

Read Less.

Only 5 left in stock
  • Specifications Main

    Main
    Range of product Easy Altivar 610
    Product or component type Variable speed drive
    Product specific application Fan, pump, compressor, conveyor
    Device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    Synchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    Type of cooling Forced convection
    Supply frequency 50...60 Hz +/-5 %
    Network number of phases 3 phases
    [Us] rated supply voltage 380...460 V - 15...10 %
    Motor power kW 55 kW for normal duty
    45 kW for heavy duty
    Motor power hp 75 hp for normal duty
    60 hp for heavy duty
    Line current 111.5 A at 380 V (normal duty)
    99.7 A at 460 V (normal duty)
    95.9 A at 380 V (heavy duty)
    84.0 A at 460 V (heavy duty)
    Prospective line Isc 22 kA
    Apparent power 79.5 kVA at 460 V (normal duty)
    66.9 kVA at 460 V (heavy duty)
    Continuous output current 88 A at 2.5 kHz for heavy duty
    120 A at 2.5 kHz for normal duty
    Maximum transient current 132 A during 60 s (heavy duty)
    132 A during 60 s (normal duty)
    Asynchronous motor control profile Optimized torque mode
    Constant torque standard
    Variable torque standard
    Output frequency 0.1…500 Hz
    Nominal switching frequency 2.5 kHz
    Switching frequency 1...8 kHz adjustable
    number of preset speeds 16 preset speeds
    Communication port protocol Modbus serial
    Option card Slot A: communication card, Profibus DP V1
    Slot A: digital or analog I/O extension card
    Slot A: relay output card
  • Complementary

    Output voltage <= power supply voltage
    Motor slip compensation Automatic whatever the load
    Adjustable
    Not available in permanent magnet motor law
    Can be suppressed
    Acceleration and deceleration ramps S, U or customized
    Linear adjustable separately from 0.01 to 9000 s
    Braking to standstill By DC injection
    Protection type Thermal protection: motor
    Motor phase break: motor
    Thermal protection: drive
    Overheating: drive
    Overcurrent between output phases and earth: drive
    Overload of output voltage: drive
    Short-circuit protection: drive
    Motor phase break: drive
    Overvoltages on the DC bus: drive
    Line supply overvoltage: drive
    Line supply undervoltage: drive
    Line supply phase loss: drive
    Overspeed: drive
    Break on the control circuit: drive
    Frequency resolution Display unit: 0.1 Hz
    Analog input: 0.012/50 Hz
    Electrical connection Control, screw terminal: 0.5...1.5 mm²
    Line side, screw terminal: 70...120 mm²
    Motor, screw terminal: 70...120 mm²
    Connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    Physical interface 2-wire RS 485 for Modbus serial
    Transmission frame RTU for Modbus serial
    Transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    Type of polarization No impedance for Modbus serial
    Number of addresses 1…247 for Modbus serial
    Method of access Slave
    Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
    Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    Local signalling 2 LEDs for local diagnostic
    1 LED (yellow) for embedded communication status
    2 LEDs (dual colour) for communication module status
    1 LED (red) for presence of voltage
    Width 290 mm
    Height 762 mm
    922 mm with EMC plate
    Depth 323 mm
    Net weight 53 kg
    Analogue input number 3
    Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
    AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
    AI2, AI3 software-configurable temperature probe or water level sensor
    Discrete input number 6
    Discrete input type DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
    DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    Input compatibility DI1...DI6: logic input level 1 PLC conforming to IEC 61131-2
    DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    Discrete input logic Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
    Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
    Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    Analogue output number 2
    Analogue output type Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
    Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
    Sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
    2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
    5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
    10 ms +/- 1 ms (AQ1, AQ2) - analog output
    Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
    +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
    AQ1, AQ2: +/- 0.2 % for analog output
    Relay output number 3
    Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
    Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
    Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
    Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
    Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
    Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    Isolation Between power and control terminals
    Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
  • Environment

    Noise level 78 dB conforming to 86/188/EEC
    Power dissipation in W 969 W(forced convection) at 380 V, switching frequency 2.5 kHz
    131 W(natural convection) at 380 V, switching frequency 2.5 kHz
    Volume of cooling air 295 m3/h
    Operating position Vertical +/- 10 degree
    Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
    1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
    Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    Pollution degree 2 conforming to IEC 61800-5-1
    Vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
    1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
    Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    Ambient air temperature for operation -15…45 °C (without derating)
    45…60 °C (with derating factor)
    ambient air temperature for storage -40…70 °C
    Operating altitude <= 1000 m without derating
    1000...4800 m with current derating 1 % per 100 m
    Environmental characteristic Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3
    Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
    Standards IEC 61800-3
    Environment 2 category C3 IEC 61800-3
    IEC 61800-5-1
    IEC 60721-3
    Marking CE
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 47.000 cm
    Package 1 Width 59.000 cm
    Package 1 Length 87.000 cm
    Package 1 Weight 70.500 kg
  • Properties

    variable speed drive ATV610 - 55 kW/75 HP - 380...415 V - IP20

    • Compact size
    • Easy and quick installation
    • User-friendly graphic display terminal
    • Easy integration on an enclosure door
    • Colored control circuit terminals to avoid misuse
    • 1 week delivery time