top of page
A9F75216

A9F75216

SKU: TR
$12.53Price

A9F75216 - scheinder

iC60N - miniature circuit breaker - 2P - 16A - D curve

stock:9

Description

This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 16A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 20kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Only 9 left in stock
  • Specifications Main

    Main
    Device application Distribution
    Range Acti9
    Product name Acti9 iC60
    Product or component type Miniature circuit-breaker
    Device short name IC60N
    Poles description 2P
    Number of protected poles 2
    [In] rated current 16 A
    Network type DC
    AC
    Trip unit technology Thermal-magnetic
    Curve code D
    Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
    36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
    10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
    10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
    20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
    6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
    36 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
    Utilisation category Category A conforming to EN 60947-2
    Category A conforming to IEC 60947-2
    Suitability for isolation Yes conforming to EN 60898-1
    Yes conforming to EN 60947-2
    Yes conforming to IEC 60898-1
    Yes conforming to IEC 60947-2
    Standards EN 60947-2
    IEC 60898-1
    IEC 60947-2
    EN 60898-1
    Complementary
    Network frequency 50/60 Hz
    Magnetic tripping limit 12 x In +/- 20 %
    [Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
    7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
    4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
    15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
    7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
    4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
    27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
    27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
    6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz
    6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz
    10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC
    10 kA 100 % conforming to EN 60947-2 - 72...125 V DC
    [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
    500 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
    6 kV conforming to IEC 60947-2
    Contact position indicator Yes
    Control type Toggle
    Local signalling Trip indicator
    Mounting mode Fixed
    Mounting support DIN rail
    Comb busbar and distribution block compatibility Top or bottom: YES
    9 mm pitches 4
    Height 85 mm
    Width 36 mm
    Depth 78.5 mm
    Net weight 0.25 kg
    Colour White
    Mechanical durability 20000 cycles
    Electrical durability 10000 cycles
    Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
    Single terminal (top or bottom) 1…16 mm² flexible
    Wire stripping length 14 mm for top or bottom connection
    Tightening torque 2 N.m top or bottom
    Earth-leakage protection Separate block
  • Environment and Packing Units

    Environment
    IP degree of protection IP20 conforming to IEC 60529
    IP20 conforming to EN 60529
    Pollution degree 3 conforming to EN 60947-2
    3 conforming to IEC 60947-2
    Overvoltage category IV
    Tropicalisation 2 conforming to IEC 60068-1
    Relative humidity 95 % at 55 °C
    Operating altitude 0...2000 m
    Ambient air temperature for operation -35…70 °C
    Ambient air temperature for storage -40…85 °C
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 7.500 cm
    Package 1 Width 3.500 cm
    Package 1 Length 9.500 cm
    Package 1 Weight 217.000 g
    Unit Type of Package 2 BB1
    Number of Units in Package 2 6
    Package 2 Height 8.000 cm
    Package 2 Width 10.000 cm
    Package 2 Length 22.300 cm
    Package 2 Weight 1.363 kg
    Unit Type of Package 3 S03
    Number of Units in Package 3 66
    Package 3 Height 30.000 cm
    Package 3 Width 30.000 cm
    Package 3 Length 40.000 cm
    Package 3 Weight 15.575 kg
  • properties

    Poles description:2P

    [In] rated current:16 A

    Curve code:D

    Suitability for industrial isolation according to IEC/EN 60947-2 standard

    Combine short-circuit and overload currents protection

    notification_ok

    Visitrip system for fast detection of faulty outgoers for shorter repair times

    VisiSafe system for offering enhanced security when it comes to circuit protection

    Option to add auxiliaries, remote monitoring and residual current device (Vigi)

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page