top of page
A9D34610

A9D34610

SKU: TR
$29.33Price

A9D34610 - scheinder

Residual current protection fuse (RCBO) iDPNa Vigi - 1P + N - 10A - 30mA class AC

stock:327

description

Earth leakage protection class AC type 30mA sensitivity Earth leakage protection time delay is instantaneous Icn class short circuit breaking capacity is up to 4500A according to EN/IEC 61009-2-1 This product provides protection against short circuit, cable overload, electric shock caused by indirect contact and fire hazards The earth fault indicator on the front face allows rapid identification of the assumed fault type It offers a safe, reliable solution for commercial and industrial applications with its high breaking capacity This product complies with EN/IEC 61009-2-1 standard Electrical endurance up to 20000 cycles and mechanical endurance up to 20000 cycles Ue operating voltage 220VAC to 240VAC Rated insulation voltage 400VAC Uimp rated impulse withstand voltage 4kV DIN rail mounting possible Width is 4 at 9mm level Product colour is white (RAL9003) Dimensions (W) 36mm x (H) 85mm x (D) 73mm Weight 125g IP20 Protection degree Becomes IP40 once in the modular box according to IEC/EN 60529 Standard Operating temperature -5°C to 60°C Storage temperature -40°C to 85°C.

  • Specifications Main

    Main

    sherry Act 9
    product name Acti9 iDPN Vigi
    Product or component type Residual current breaker (RCBO) with overcurrent protection
    Product group iDPNa Vigi
    device application Distribution
    Definition of pole 1P + N
    number of protected poles 1
    neutral position Left
    [In] nominal current 10 A
    Network type HUNGRY
    opening unit technology Thermal Magnetic
    slope code C
    earth leakage sensitivity 30mA
    earth leakage protection time delay Momentary
    earth leakage protection class AC type
    cutting capacity 4500 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
    suitability for insulation Yes conforming to EN/IEC 60947-2

    Complement

    Complementary Exit
    Network frequency 50Hz
    [Ue] nominal operating voltage 230...240V AC 50Hz
    magnetic opening limit 5...10 x In
    residual current tripping technology Voltage independent
    [Ics] nominal service interrupting capacity 4500 A 100% x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
    hominal cutting and closing capacity Idm 4500 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
    restriction class 3 conforming to EN/IEC 61009-2-1
    [Ui] nominal insulation voltage 400V AC 50Hz
    [Uimp] rated impulse withstand voltage 4 kV
    ignition position indicator Yes
    Control type Transition
    On-device signaling ON, OFF, error opening
    Mounting Type Pluggable
    mounting support DIN rail
    comb busbar distribution block compatibility Top or bottom: YES
    connection range 9 mm between phase and neutral
    9mm screw pitch 4
    Height 85mm
    width 36mm
    depth 73mm
    product weight 125g
    colour White
    Mechanical durability 20000 cycles
    electrical resistance 20000 cycles
    Locking options definition Locking device
    connections - terminals Single terminal top or bottom1…16 mm² rigid
    Single terminal top or bottom1…10 mm² flexible
    Single terminal top or bottom1…10 mm² ferrule and flexible
    wire stripping length 15 mm for top or bottom connection
    tightening torque 2 Nm above or below
    earth leakage protection Integrated
  • Environment and Packing Units

    Environment

    Standards EN/IEC 61009-2-1
    Product certificates VDE
    IP protection degree IP20 conforming to IEC 60529
    IP40 (modular enclosure) conforming to IEC 60529
    degree of contamination 3
    overvoltage category III conforming to IEC 60364
    electromagnetic compatibility 8/20 µs impulse resistance, 250 A conforming to EN/IEC 61009-2-1
    tropical climate 2 conforming to IEC 60068-1
    relative humidity 95% at 55 °C
    ambient air temperature for operation -5…60 °C
    Storage environmental conditions -40…85 °C

    Packaging units

    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 4,000 cm
    Package 1 Width 8,500 cm
    Package 1 Length 10,000 cm
    Package 1 Weight 206,800g
    Unit Type of Package 2 S03
    Number of Units in Package 2 54
    Package 2 Height 30,000 cm
    Package 2 Width 30,000 cm
    Package 2 Length 40,000 cm
    Package 2 Weight 11,557 kg
    Unit Type of Package 3 P12
    Number of Units in Package 3 432
    Package 3 Height 45,000 cm
    Package 3 Width 80,000 cm
    Package 3 Length 120,000 cm
    Package 3 Weight 104,456 kg
  • properties

    Protection of persons against electric shock by direct contact
    Combine short circuit and overload current protection
    Suitability for insulation according to IEC 61009-1 and IEC 61009-2-1 standards
    Easy installation with unified terminal design and wiring indicator
    Ground fault indication with red mechanical indicator on the front face
No Reviews YetShare your thoughts. Be the first to leave a review.

Relpol 